| Sensor Signal
Transmitters |
Wall Mount
Temperature & Humidity |
Duct Mount
Temperature & Humidity |
Immersion / Strap-On
& Remote
Temperature |
Outside Air
Temperature & Humidity |
Analog / Digital
Signal Input Transmitter |
Energy
Monitors
&
Totalizers |
High
Temperature
Sensors |

|

|

|

|

|

|

|
Product Literature
WT1630A,B,C.pdf
WH1630A,B.pdf
(3%)
WH1630C,D.pdf
(2%)
|
Product Literature
DT1630A.pdf
DH1630A,B,C.pdf
(3%)
DH1630D,E,F.pdf
(2%)
DT1650A.pdf |
Product Literature
FT1630A.pdf
SST1630A,B,C.pdf |
Product Literature
OA1630A,
OT1630A,
OH1630A.pdf
OST1630A.pdf |
Product Literature
RT1630A,B,C,D.pdf
RT1620A.pdf |
Product Literature
EM2200A,B.pdf |
Product Literature
FT3630A,B,C,S.pdf
SST3630A.pdf |
| 900 MHZ Spread Spectrum |
900 MHZ Spread Spectrum |
900 MHZ Spread Spectrum |
900 MHZ Spread Spectrum |
900 MHZ Spread Spectrum |
900 MHZ Spread Spectrum |
900 MHZ Spread Spectrum |
Suitable for churches, museums
and historical buildings
Building retrofit applications in older buildings and hotels
Office environments where work spaces are changed frequently
Difficult installations where relocation of sensors is needed to
optimize system performance
Easy and non-intrusive installation of monitoring systems for
energy retrofit/analysis |
Works in virtually all
difficult to wire building applications
Fast installation in Mechanical Rooms - eliminates the need for
conduit
Humidity and temperature data allows DDC Controller to calculate
Enthalpy / Dew Point
Easy to relocate and install to fix tough applications
Four point wireless averaging sensor has a 20 ft. flexible probe |
Easy to install
Eliminates the need for conduit
Suitable for use with multiple fluid types - Brass or Stainless
thermowells available
Works in virtually all difficult to wire building applications
Wireless Refrigeration monitoring |
Suitable for use in all types
of DDC control applications
Eliminates the need to penetrate through exterior building walls
Can be mounted remotely from buildings
One sensor can be used with multiple DDC controllers in
different locations/buildings
Easy to relocate
Integral temperature and humidity sensors in a single unit
eliminates the need for multiple sensors
8-plate solar shield ensures accurate outside air temperature
readings
Humidity and temperature data allows DDC Controller to calculate
Enthalpy / Dew Point |
Remote wireless relay
applications where remote loads from a different building can be
controlled without trenching wires or conduit
Suitable for use with a variety of duct, water, space, status
and alarm sensors for monitoring and control
Air Handling Unit applications where multiple duct sensors,
status and alarms (OA, RA, MA, DA filter, freeze and fan status)
can easily be picked up and transmitted to the panel without
running wires or conduit
Equipment monitoring applications where pumps, fans and alarm
status can be picked up and transmitted to the panel without
running wires or conduit
Lighting applications where the occupancy sensors or lighting
loads are located in an area remote from the controls such as a
parking lot
Wireless Chiller/Boiler monitoring. |
Totalizes power meter or
energy/flow meter for energy monitoring or sub-metering
Accepts end of interval synchronization pulse for power
demand calculations
Suitable for use with power meters, BTU meters, flow meters |
NEMA4 Enclosure
Suitable for industrial process temperature measurement
,
Easy to install
Eliminates the need for conduit
Suitable for use with multiple fluid types - Brass or Stainless
thermowells available
Works in virtually all difficult to wire building applications |
Operating Voltage:
Battery (3 V LiMnO2)
Battery Life:
Temperature Only
5+years
Humidity Versions
3+years |
Operating Voltage:
Battery (3 V LiMnO2)
Battery Life:
Temperature Only
5+years
Humidity Versions
3+years |
Operating Voltage:
Battery (3 V LiMnO2)
Battery Life:
Temperature
5+years |
Operating Voltage:
Battery (3 V LiMnO2)
Battery Life:
Temperature Only
5+years
Humidity Versions
3+years |
Operating Voltage:
Battery (3 V LiMnO2)
or
24 VAC
Battery Only Models:
RT1620B & RT1631
Battery Life:
Standard Models
5+years |
Operating Voltage:
24 VAC |
Operating Voltage:
Battery (3 V LiMnO2)
Battery Life:
5+years
|
Operating Ambient:
32F to 104F
5% to 95% RH
(Non-Condensing) |
Operating Ambient:
-40F to 160F
5% to 95% RH
(Non-Condensing) |
Operating Ambient:
-40F to 160F
5% to 95% RH
(Non-Condensing) |
Operating Ambient:
-40F to 160F
5% to 95% RH
(Non-Condensing) |
Operating Ambient:
-40F to 160F
5% to 95% RH
(Non-Condensing) |
Operating Ambient:
-40F to 160F
5% to 95% RH
(Non-Condensing) |
Operating Ambient:
-40F to 160F
5% to 95% RH
(Non-Condensing) |
Input:
20k NTC Thermistor (Included)
Capacitive Humidity Element (Included) |
Input:
20k NTC Thermistor (Included)
Capacitive Humidity Element (Included) |
Input:
20k NTC Thermistor (Included) |
Input:
20k NTC Thermistor (Included)
Capacitive Humidity Element (Included) |
Input:
(4) Analog - 20k NTC Thermistor, 0-10VDC, 0-5VDC
(4) Digital-Relay Contacts
RT1631A
(1) Analog (0-10VDC)
(1) Digital (Relay Contacts)
RT1631B
(2) Analog (20Kohm & 0-10VDC) |
Input:
(2) Totalizer Inputs
(3 bytes)
10 Hz Max
(2) Digital |
Input:
Platinum 1000 Ohm RTD (Included) |
Output:
RF Transmission of:
Temperature
(32F to 104F +/- 1F)
Humidity
(10% to 90% +/-3%)
(30% to 80% +/-2%)
Low Battery Indication
Setpoint Models - Warmer/Cooler or
65F to 85F
Occupancy Override
Low Battery Indication |
Output:
RF Transmission of:
Temperature
(-40F to 160F +/- 1F)
(25F to 150F +/- 1F)
Humidity
(10% to 90% +/-3%)
(30% to 80% +/-2%)
Low Battery Indication |
Output:
RF Transmission of:
Temperature
(0F to 200F +/- 1F)
(25F to 125F +/- 1F)
Low Battery Indication |
Output:
RF Transmission of:
Temperature
(-40F to 160F +/- 1F)
Humidity
(10% to 90% +/-3%)
Low Battery Indication |
Output:
RF Transmission of:
(4) Analog
(20K Thermister
10K Thermister
1K RTD
0-5VDC
0-10VDC)
(4) Digital (Relay Contacts)
Low Transmitter Battery Indication
RT1631A
(1) Analog (0-10VDC)
(1) Digital (Relay Contacts)
RT1631B
(2) Analog (20Kohm & 0-10VDC)
Low Battery Indication |
Output:
RF Transmission of:
(2) Totalizer Count
(2) Digital (Relay Contacts)
Low Battery Indication
|
Output:
RF Transmission of:
Temperature
(0F to 250F)
(-40F to 160F)
(-100F to 1100F)
Low Battery Indication
|